Sterilization and disinfectant bench

BCSEPick an item and a pathogen to see which sterilization method or disinfectant works, contact times, and which organisms (spores, prions, non-enveloped viruses) resist each one.

  1. 1
    You change

    Pick an item, an organism and a method, then set the contact time, temperature or dilution and whether the item was cleaned first.

  2. 2
    Inside

    Each method kills by a different mechanism. Organisms with tougher coats (spores, waxy walls, no envelope) die more slowly or not at all.

  3. 3
    The readout

    The culture plate and kill curve show how many organisms survive, the level of kill reached, and whether it is enough for that item.

1 · Item or surface

2 · Organism (most resistant at the top)

3 · Method or agent

Plate: 1 million organisms at the start.
Log reduction
0log
Survivors of 106
106
Level of kill
None
Item needs
Sterilization

Log scale, 6 seconds to 24 hours.
100 °C is boiling: it does not kill spores.
Before treatment
Feces, blood, pus and bedding shield organisms and inactivate many agents.

Kill curve: survivors over time (log scales)

Chosen organismBacterial sporesEnveloped virusesDashed lines: 1 survivor, and the sterility assurance level of 10−6

Illustrative kill curves built from each agent’s efficacy against each organism group at typical label conditions. They show the principle; product labels give the real claims and contact times.

What happens inside

Every step must succeed. A red box is where the kill fails for the current choice.


Pick a problem

Starting point

A surgical instrument pack in a steam autoclave at 121 °C for 15 minutes, cleaned first, tested against bacterial spores. Change one thing at a time: drop the temperature to 100 °C, shorten the time, or make it dirty, and watch the colonies come back.


Go further

Sort by where the item goes. Into sterile tissue or blood: critical. Onto mucous membranes or broken skin: semicritical. Only onto intact skin: noncritical.

Spaulding classification

CategoryContactMinimum
CriticalSterile tissue, body cavities, bloodSterilization
SemicriticalMucous membranes, non-intact skinHigh-level disinfection
NoncriticalIntact skin only, or no patient contactLow or intermediate-level disinfection

Study notes

Methods and agents

Sterilization methods

Typical cycle conditions; follow the sterilizer manufacturer.

MethodTypical conditionsKills byGood forWatch out
Steam autoclaveMoist heat under pressure121 °C for at least 15 min (longer for wrapped packs); 132 to 134 °C for 3 to 4 min (prevacuum or flash)Protein coagulationHeat- and moisture-stable instruments, drapes, gownsAir pockets and overpacked loads block steam; biological indicator Geobacillus stearothermophilus
Dry heat160 °C for 2 h or 170 °C for 1 hOxidationGlassware, powders, oils, sharp instruments that steam would dull or rustSlow; damages plastics and rubber; indicator Bacillus atrophaeus
Ethylene oxide gasLow temperature (about 30 to 60 °C), humidity, hours of exposureAlkylation of proteins and DNAHeat-sensitive items: plastics, endoscopes, power tools, cathetersToxic, carcinogenic, flammable; items need aeration (often 12 h or more) before use; indicator B. atrophaeus
Hydrogen peroxide gas plasmaLow temperature, cycles of about 30 to 75 minOxidation (free radicals)Heat-sensitive metal and plastic items; no aeration neededNo paper, linen, cellulose or liquids; long narrow lumens limited
Glutaraldehyde 2% (cold sterilant)High-level disinfection in about 20 to 45 min; sterilization needs about 10 hAlkylationEndoscopes and other semicritical heat-sensitive itemsIrritant to skin and airways; rinse items with sterile water; not for surfaces or skin
Gamma irradiationIndustrialDNA damageCommercial single-use items: suture, needles, syringes, glovesNot available in clinics; do not resterilize single-use items

Disinfectants and antiseptics

Typical teaching summary; the product label is the legal guide for dilution and contact time.

AgentNon-enveloped virusesMycobacteriaSporesOrganic matterNotes
Sodium hypochlorite (bleach)Yes (1:32)VariableAt high strength (1:10)InactivatedParvovirus, calicivirus; 10 min contact; corrosive; never mix with ammonia or acids (toxic gas)
Accelerated hydrogen peroxideYesYesSome productsFairly tolerantBroad spectrum, short contact times, low toxicity; also a detergent
Potassium peroxymonosulfateYesLimitedNoModerateOxidizer; farms, footbaths, kennels
Quaternary ammoniumNo (not parvovirus)NoNoInactivated (also by soap, hard water)Enveloped viruses, gram-positive bacteria; weaker on gram-negatives; cheap and low odor
PhenolicsPoorYesNoTolerantToxic to cats Useful in barns with organic soiling, tuberculosis and Johne’s disease
Alcohol 70%PoorYesNoReducedFast; evaporates, so contact is short; 70% works better than 95% (water needed to denature proteins); flammable
ChlorhexidineNoNoNoFairly tolerantAntiseptic for skin and hands; binds skin for residual activity; ototoxic in the middle ear
Povidone-iodine (iodophor)VariableVariableWith long contactInactivatedSkin preparation; little residual activity; can irritate skin; avoid in iodine-sensitive patients

Resistance ladder

Most resistant at the top.

OrganismsExamples
PrionsScrapie, chronic wasting disease, BSE
Bacterial sporesClostridium, Bacillus anthracis
Protozoal oocystsCryptosporidium, coccidia
MycobacteriaM. bovis, M. avium subsp. paratuberculosis
Small non-enveloped virusesParvoviruses, calicivirus
Fungal sporesMicrosporum canis, Aspergillus
Gram-negative bacteriaPseudomonas, Salmonella, E. coli
Gram-positive bacteriaStaphylococcus, Streptococcus equi
Enveloped virusesInfluenza, canine distemper, herpesviruses, coronaviruses, rabies

Words that get mixed up

TermMeaning
CleaningRemoving organic matter and most organisms with detergent and scrubbing; always first
DisinfectionKilling most pathogens on objects and surfaces, not necessarily spores
AntisepsisReducing organisms on living tissue (skin, mucosa)
SterilizationDestroying all microbial life, including spores; sterility assurance level 10−6 (a one in a million chance of one survivor)
SanitizationLowering organisms to a level judged safe for public health (food surfaces)
-cidal vs -staticKills vs stops growth
D valueTime at a set condition to kill 90% (one log) of a population

Memory hooks

  • Clean before you disinfect. No agent works well through dirt.
  • Critical, semicritical, noncritical: sterilize, high-level disinfect, low-level disinfect.
  • Parvovirus shrugs off quats; use bleach 1:32, accelerated hydrogen peroxide or peroxymonosulfate.
  • Phenolics for mycobacteria, never around cats.
  • Prions beat the standard autoclave: incinerate, or sodium hydroxide plus extended autoclaving.
  • Boiling is not sterilization: spores survive.
  • Tape shows the pack was processed, not that it is sterile. Only a biological indicator shows the kill.
  • Enveloped viruses are the easiest to kill; almost any disinfectant works.
  • Chlorhexidine stays on the skin; povidone-iodine does not.

Exam check

For exam study only. Simplified teaching models: do not use these tools to make decisions for real patients. Last reviewed November 2026.

More free tools in the Vet Lab

ECG Rhythm Bench Acid-Base and Blood Gas Interpreter Fluid Plan and CRI Builder Diagnostic Test Bench Pharmacokinetics Bench Anaesthesia Machine and Capnograph Nephron and Diuretic Sites Clotting Cascade and Test Bench Spinal Cord Lesion Localiser Bovine Ping Map Estrous Cycle and Synchronization Poison Clock Adrenal Test Bench MAC and Inhalant Uptake Autonomic Receptor Board Chemistry Panel Patterns Dystocia Manipulator Transition Cow Metabolic Simulator Drug Withdrawal and Extra-Label Use Equine Nerve Block Ladder X-ray Exposure Console Suture Selector and Wound Healing Euthanasia Method Matrix Urinalysis Bench Anemia Workup Outbreak Sandbox Maternal Antibody and Vaccine Timing Dentition Builder Fish Tank Water Quality